00779
From Ross-Tech Wiki
Table Of Contents
-
1.
00779 - Outside Air Temperature Sensor (G17)
-
1.1.1
00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
-
1.2.1
00779 - Outside Air Temperature Sensor (G17): Short to Ground
- 1.2.1.6 Possible Symptoms
- 1.2.2.6 Possible Causes
- 1.2.3.6 Possible Solutions
-
1.1.1
00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus
00779 - Outside Air Temperature Sensor (G17)
00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster: Open or Short Circuit
Possible Solutions
- Check wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster
- Check Measuring Block Value
00779 - Outside Air Temperature Sensor (G17): Short to Ground
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Outside Air Temperature Sensor (G17) damaged
Possible Solutions
- Check / Replace Outside Air Temperature Sensor (G17)