VW Golf (1J) Brake Electronics (MK20)
Coding
- Due to all of the Coding MK20 variants, it is recommended to use the coding from the original module when replacing the ABS module. Save the complete Auto-Scan before repairs.
- If you are having trouble finding/calculating the proper Coding please:
- Refer to the Factory Repair Manual for Coding information.
- Registered users that need assistance configuring the Coding can send the before and after replacement Auto-Scans to Support for assistance.
Basic Setting
Sensor for Steering Angle (G85)
Prerequisites:
- Start the vehicle.
- Turn the steering wheel one turn to the right and one turn to the left.
- Drive in a short distance straight line on a level surface at a speed not higher than 20 km/h.
- If the steering wheel is straight during the test drive then stop the vehicle with the wheels pointed straight.
- Ensure that the steering wheel is not moved again.
- Keep the engine running and do not switch off the ignition.
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 060
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 1, the value has to be between -4.5 and +4.5 °.
[Done, Go Back]
[Close Controller, Go Back - 06]
Lateral Acceleration Sensor (G200)
Prerequisites:
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 063
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]
Brake Pressure Sensor 1 (G201)
Prerequisites:
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 066
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -7.0 and +7.0 bar.
[Done, Go Back]
[Close Controller, Go Back - 06]
Longitudinal Acceleration Sensor (G251)
Prerequisites:
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 069
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 006
[Go!]
Check field 1, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]