VW Golf (1K) Auxiliary Heating
From Ross-Tech Wiki
(Redirected from VW Touran (1T) Auxiliary Heating)
Coding
Adaptation
Basic Setting
Function Test (Customer Service Start)
Prerequisites:
- Climate Control OFF
- Enough Fuel in Fuel Tank (clearly NOT on reserve)
- Battery charged
- Coolant Temperature below 60 °C
- Do NOT disconnect VAG-COM while performing this procedure.
[Select]
[18 - Aux. Heater]
[Basic Settings - 04]
Group 011
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
Observe Field 3, it represents the current status of the system.
[Done, Go Back]
[Close Controller, Go Back - 06]