<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.ross-tech.com/wiki/index.php?action=history&amp;feed=atom&amp;title=C1046%2F020550</id>
	<title>C1046/020550 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.ross-tech.com/wiki/index.php?action=history&amp;feed=atom&amp;title=C1046%2F020550"/>
	<link rel="alternate" type="text/html" href="https://wiki.ross-tech.com/wiki/index.php?title=C1046/020550&amp;action=history"/>
	<updated>2026-05-25T16:46:40Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.3</generator>
	<entry>
		<id>https://wiki.ross-tech.com/wiki/index.php?title=C1046/020550&amp;diff=9423&amp;oldid=prev</id>
		<title>Peter: Created page with &quot;__FORCETOC__ == C1046/020550 - Ride-Height System; Plausibility Error ==  ==== Possible Symptoms ====  * Lever Control dash warning * Ride height drops or does not respond  ==...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.ross-tech.com/wiki/index.php?title=C1046/020550&amp;diff=9423&amp;oldid=prev"/>
		<updated>2023-12-05T18:03:29Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;__FORCETOC__ == C1046/020550 - Ride-Height System; Plausibility Error ==  ==== Possible Symptoms ====  * Lever Control dash warning * Ride height drops or does not respond  ==...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;__FORCETOC__&lt;br /&gt;
== C1046/020550 - Ride-Height System; Plausibility Error ==&lt;br /&gt;
&lt;br /&gt;
==== Possible Symptoms ====&lt;br /&gt;
&lt;br /&gt;
* Lever Control dash warning&lt;br /&gt;
* Ride height drops or does not respond&lt;br /&gt;
&lt;br /&gt;
==== Possible Causes ====&lt;br /&gt;
&lt;br /&gt;
* Air Leak (Air struts, lines, fittings, etc.)&lt;br /&gt;
* Weak compressor (not enough air pressure)&lt;br /&gt;
* Valve Block (water damage, stuck valves, etc.)&lt;br /&gt;
* Level Sensors (loose, installed backwards, etc.)&lt;br /&gt;
&lt;br /&gt;
==== Possible Solutions ====&lt;br /&gt;
&lt;br /&gt;
* Check for and repair as needed any Air Leaks&lt;br /&gt;
* Verify compressor operation with Output Tests&lt;br /&gt;
* Verify Valve Block solenoids operation with Output Tests&lt;br /&gt;
* Check Level Sensor plausibility using Measuring Values&lt;br /&gt;
&lt;br /&gt;
==== Special Notes ====&lt;br /&gt;
&lt;br /&gt;
* The fault code C1046 will set if the Level Control module detects instances of uncontrolled height changes (such as due to leakage) or when the height remains unchanged despite a control request.&lt;/div&gt;</summary>