Difference between revisions of "01336"

From Ross-Tech Wiki
m
Line 6: Line 6:
 
==== Possible Causes ====
 
==== Possible Causes ====
  
- Databus working in Single-Wire Mode<br>
+
- CAN-Databus faulty<br>
 +
- Open Circuit or Short to Ground/Plus in Wiring<br>
 +
- Wiring damage<br>
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====

Revision as of 01:07, 22 November 2005

01336 - Data Bus for Comfort System

01336 - Data Bus for Comfort System: Faulty

Possible Causes

- CAN-Databus faulty
- Open Circuit or Short to Ground/Plus in Wiring
- Wiring damage

Possible Solutions

- Check CAN-Gateway Coding
- Check Measuring Groups
- Check Wiring/Control Modules

01336 - Data Bus for Comfort System: Single-Wire Operation

Possible Causes

- Databus working in Single-Wire Mode

Possible Solutions

- Check Measuring Blocks
- Check Wiring/Control Modules

--Sebastian 01:04, 22 November 2005 (Eastern Standard Time)