01331: Difference between revisions

New page: __FORCETOC__ == 01331 - Door Control Module; Driver Side (J386) == === 01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low === ==== Possible Causes ==== * Fuse(s) fa...
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 21: Line 21:
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
=== 01331 - Door Control Module; Driver Side (J386): Faulty ===
==== Possible Causes ====
* Fuse(s) faulty
* Wiring/Connectors from/to Control Module faulty
* Door Control Module Driver Side (J386) faulty
==== Possible Solutions ====
* Check Fuse(s)
* Check/Repair Wiring/Connectors from/to Control Module
* Check Door Control Module Driver Side (J386)
=== 01331 - Door Control Module; Driver Side (J386): Single-Wire Operation ===
==== Possible Symptoms ====
* Data Bus Comfort working in Single-Wire Mode
==== Possible Causes ====
* Wiring/Connectors from/to Door Control Module Driver Side (J386)
* Control Module in CAN Data Bus Comfort faulty
==== Possible Solutions ====
* Check Measuring Value Blocks (MVB)
* Check Wiring/Connectors from/to Door Control Module Driver Side (J386)


[[Category:Fault Codes]]
[[Category:Fault Codes]]

Latest revision as of 11:58, 22 March 2009

01331 - Door Control Module; Driver Side (J386)

01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low

Possible Causes

  • Fuse(s) faulty
  • Wiring/Connectors from/to Control Module faulty
  • Power Supply (Battery/Generator) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Repair Wiring/Connectors from/to Control Module
  • Check Power Supply (Battery/Generator)

Special Notes

  • When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
  • When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
  • Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.


01331 - Door Control Module; Driver Side (J386): Faulty

Possible Causes

  • Fuse(s) faulty
  • Wiring/Connectors from/to Control Module faulty
  • Door Control Module Driver Side (J386) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Repair Wiring/Connectors from/to Control Module
  • Check Door Control Module Driver Side (J386)


01331 - Door Control Module; Driver Side (J386): Single-Wire Operation

Possible Symptoms

  • Data Bus Comfort working in Single-Wire Mode

Possible Causes

  • Wiring/Connectors from/to Door Control Module Driver Side (J386)
  • Control Module in CAN Data Bus Comfort faulty

Possible Solutions

  • Check Measuring Value Blocks (MVB)
  • Check Wiring/Connectors from/to Door Control Module Driver Side (J386)