01814: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) Created page with '== 01814 - Supply Voltage for Door Controller; Rear Right (J389) == === 01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded === ==== Possible Sy…' |
RtWiKiSyS0p (talk | contribs) mNo edit summary |
||
Line 16: | Line 16: | ||
* Check Fuse(s) | * Check Fuse(s) | ||
** Check Door Controller Rear Right (J389) Measuring Value | ** Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB) | ||
* Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389) | * Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389) | ||
__FORCETOC__ | __FORCETOC__ | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 04:06, 5 December 2010
01814 - Supply Voltage for Door Controller; Rear Right (J389)
01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded
Possible Symptoms
- Door Controller Functionality limited
- Window Regulator not working
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Door Controller Rear Right (J389) faulty
Possible Solutions
- Check Fuse(s)
- Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB)
- Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)