Difference between revisions of "19558/P3102/012546"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) |
||
(One intermediate revision by one other user not shown) | |||
Line 4: | Line 4: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
− | * Hard | + | * Hard Shudder when turning OFF the Engine |
==== Possible Causes ==== | ==== Possible Causes ==== | ||
− | * Wiring/ | + | * Fuse(s) faulty |
+ | * Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) faulty | ||
+ | * Intake Manifold Flap Motor (V157) faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
− | * Check Wiring/ | + | * Check Fuse(s) |
− | * Check | + | * Check Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) |
+ | * Check/Replace Intake Manifold Flap Motor (V157) | ||
** Perform Output Test | ** Perform Output Test | ||
+ | __FORCETOC__ | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 16:26, 11 July 2011
19558/P3102/012546 - Motor for Intake Manifold Flap (V157): No Signal
Possible Symptoms
- Hard Shudder when turning OFF the Engine
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) faulty
- Intake Manifold Flap Motor (V157) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157)
- Check/Replace Intake Manifold Flap Motor (V157)
- Perform Output Test