17971/P1563/005475: Difference between revisions
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
- 
          
          1.
          17971/P1563/005475 - Quantity Adjuster (N146): Lower Limit Reached
          
- 1.1.1 Possible Symptoms
 
- 1.2.1 Possible Causes
 
- 1.3.1 Possible Solutions
 
- 1.4.1 Notes
 
 
| Line 25: | Line 25: | ||
* On the 1.9L ALH TDI engine:    | * On the 1.9L ALH TDI engine:    | ||
** The Quantity Adjuster (N146) should ohm test between .5 and 2.5 Ω.  | ** The Quantity Adjuster (N146) should ohm test between 0.5 and 2.5 Ω.  | ||
** With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts.     | ** With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts.     | ||
[[Category:Fault Codes]]  | [[Category:Fault Codes]]  | ||
Latest revision as of 21:26, 17 August 2011
17971/P1563/005475 - Quantity Adjuster (N146): Lower Limit Reached
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
 - Reduced Power
 - Engine jerking
 
Possible Causes
- Fuse(s) faulty
 - Wiring and/or Connector(s) from/to Quantity Adjuster (N146) faulty
 - Quantity Adjuster (N146) not adjusted
 - Quantity Adjuster (N146) blocked/faulty
 
Possible Solutions
- Check Fuse(s)
 - Check Wiring and/or Connector(s) from/to Quantity Adjuster (N146)
 - Check/Adjust Quantity Adjuster (N146)
 - Check/Replace Injection Pump
 
Notes
- On the 1.9L ALH TDI engine:
- The Quantity Adjuster (N146) should ohm test between 0.5 and 2.5 Ω.
 - With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts.