== 17911/P1503 - Load signal from Alternator Term. DF: Range/Performance / Implausible Signal ==
 
== 17911/P1503 - Load signal from Alternator Term. DF: Range/Performance / Implausible Signal ==
 
==== Possible Symptoms ====
 
 
* unknown
 
  
 
==== Possible Causes ====
 
==== Possible Causes ====
Line 17: Line 13:
 
* Check / Replace Voltage Regulator
 
* Check / Replace Voltage Regulator
 
* Check wiring and connections
 
* Check wiring and connections
 +
* Check the fuse box that is in the battery tray, it might be burnt, the fuse or the complete plastic box (pretty common failure on Sharan because it carries so much electrical load). If so, change the complete fuse box, it is not too expensive fix if this is the cause.
 +
 +
==== Special Notes ====
 +
 +
* When found on the BEW engine, check MVB 16, Field 1.  In most cases values will be between 15% to 30% at idle.  0% could indicate a failed or incorrect alternator.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 14:12, 30 November 2011

17911/P1503 - Load signal from Alternator Term. DF: Range/Performance / Implausible Signal

Possible Causes

  • Alternator faulty
  • Voltage Regulator faulty
  • Wiring and/or connections faulty

Possible Solutions

  • Check / Replace Alternator
  • Check / Replace Voltage Regulator
  • Check wiring and connections
  • Check the fuse box that is in the battery tray, it might be burnt, the fuse or the complete plastic box (pretty common failure on Sharan because it carries so much electrical load). If so, change the complete fuse box, it is not too expensive fix if this is the cause.

Special Notes

  • When found on the BEW engine, check MVB 16, Field 1. In most cases values will be between 15% to 30% at idle. 0% could indicate a failed or incorrect alternator.