Difference between revisions of "00667"

From Ross-Tech Wiki
(New page: __FORCETOC__ == 00667 - Ambient Temperature Signal == === 00667 - Ambient Temperature Signal: Implausible Signal === ==== Possible Causes ==== * Wiring and/or Connector(s) from/to Instr...)
 
 
Line 7: Line 7:
  
 
* Wiring and/or Connector(s) from/to Instrument Cluster (J285) faulty
 
* Wiring and/or Connector(s) from/to Instrument Cluster (J285) faulty
* Wiring and/or Connector(s) from/to Ambient Temperature Senor (G17) faulty
+
* Wiring and/or Connector(s) from/to Ambient Temperature Sensor (G17) faulty
* Ambient Temperature Senor (G17) faulty  
+
* Ambient Temperature Sensor (G17) faulty  
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
Line 14: Line 14:
 
* Check Instrument Cluster (J285) for Fault Codes
 
* Check Instrument Cluster (J285) for Fault Codes
 
* Check Wiring and/or Connector(s) from/to Instrument Cluster (J285)
 
* Check Wiring and/or Connector(s) from/to Instrument Cluster (J285)
* Check Wiring and/or Connector(s) from/to Ambient Temperature Senor (G17)
+
* Check Wiring and/or Connector(s) from/to Ambient Temperature Sensor (G17)
* Check/Replace Ambient Temperature Senor (G17)
+
* Check/Replace Ambient Temperature Sensor (G17)
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 23:58, 24 July 2012

00667 - Ambient Temperature Signal

00667 - Ambient Temperature Signal: Implausible Signal

Possible Causes

  • Wiring and/or Connector(s) from/to Instrument Cluster (J285) faulty
  • Wiring and/or Connector(s) from/to Ambient Temperature Sensor (G17) faulty
  • Ambient Temperature Sensor (G17) faulty

Possible Solutions

  • Check Instrument Cluster (J285) for Fault Codes
  • Check Wiring and/or Connector(s) from/to Instrument Cluster (J285)
  • Check Wiring and/or Connector(s) from/to Ambient Temperature Sensor (G17)
  • Check/Replace Ambient Temperature Sensor (G17)