Difference between revisions of "01407"

From Ross-Tech Wiki
(Created page with "== 01407 - Flame Extinguished == ==== Possible Symptoms ==== * Auxiliary/Parking Heater not working * Auxiliary/Parking Heater smokes ==== Possible Causes ==== * Air/Bubbl...")
 
m
 
Line 10: Line 10:
 
* Air/Bubbles in Fuel System/Supply (possibly due to low Fuel Level)
 
* Air/Bubbles in Fuel System/Supply (possibly due to low Fuel Level)
 
* Fuel System/Supply faulty/leaking
 
* Fuel System/Supply faulty/leaking
* Metering Pump (V54) faulty
 
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
Line 17: Line 16:
 
* Test/Run Auxiliary/Parking Heater
 
* Test/Run Auxiliary/Parking Heater
 
** Perform Output Test/Basic Setting
 
** Perform Output Test/Basic Setting
* Check/Replace Metering Pump (V54)
 
  
 
==== Special Notes ====
 
==== Special Notes ====

Latest revision as of 09:23, 19 May 2013

01407 - Flame Extinguished

Possible Symptoms

  • Auxiliary/Parking Heater not working
  • Auxiliary/Parking Heater smokes

Possible Causes

  • Air/Bubbles in Fuel System/Supply (possibly due to low Fuel Level)
  • Fuel System/Supply faulty/leaking

Possible Solutions

  • Check/Repair Fuel System/Supply
  • Test/Run Auxiliary/Parking Heater
    • Perform Output Test/Basic Setting

Special Notes

  • Make sure the Car has only been driven with the correct Fuel (for example Bio Diesel may not be permitted).