Difference between revisions of "P068A/001674"

From Ross-Tech Wiki
(Created page with '== P068A/001674 - ECM Power Relay Load Circuit: De-Energized Performance Too Early == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) ON ==== Possible Causes =…')
 
Line 17: Line 17:
 
* Check Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317)  
 
* Check Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317)  
 
* Check/Replace Power Supply Relay (J271/J317)  
 
* Check/Replace Power Supply Relay (J271/J317)  
 +
 +
 +
 +
'''''Note:'''  A weak Battery may set this fault code. Insure the Battery voltage is at least 11.5v. ''<br><br><br>
 +
 +
  
 
__FORCETOC__
 
__FORCETOC__
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 14:41, 26 August 2013

P068A/001674 - ECM Power Relay Load Circuit: De-Energized Performance Too Early

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Fuse(s) faulty
  • Ignition Switch faulty
  • Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317) faulty
  • Power Supply Relay (J271/J317) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Power Supply Relay (J271/J317)
  • Check/Replace Power Supply Relay (J271/J317)


Note: A weak Battery may set this fault code. Insure the Battery voltage is at least 11.5v.