* Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness. | * Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 10:48, 12 March 2014
18237/P1829 - Pressure Control Valve 4 (N218): Open/Short to Ground
Possible Causes
- Wiring from/to Pressure Control Valve 4 (N218) Open/Short to Ground
- Pressure Control Valve 4 (N218) faulty
Possible Solutions
- Check Wiring from/to Pressure Control Valve 4 (N218)
- Check Pressure Control Valve 4 (N218)
- Check Measuring Blocks
Special Notes
- Pressure Control Valve 4 (N218) might be referred to as Solenoid Valve 7 (N94)
- Some 02E transmissions (DSG) will not have (N218) or (N94) listed in the factory repair manual. It is part of the Mechatronics Unit.
- Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness.