01273: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
01273 - Fresh Air Blower (V2)
- 1.1.1 Possible Causes
- 1.2.1 Possible Solutions
- 1.3.1 Special Notes
RtWiKiSyS0p (talk | contribs) mNo edit summary |
|||
(5 intermediate revisions by 3 users not shown) | |||
Line 6: | Line 6: | ||
* Fresh Air Blower (V2) defective | * Fresh Air Blower (V2) defective | ||
* Control Module for Fresh Air Blower (J126) defective | * Control Module for Fresh Air Blower (J126) defective | ||
* Short of open circuit in wiring to Fresh Air Blower (V2) | |||
* Climatronic Control Module (J255) malfunctioning | |||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
Line 14: | Line 16: | ||
* Check Control Module for Fresh Air Blower (J126) | * Check Control Module for Fresh Air Blower (J126) | ||
** Perform Output Test (Check Air Vents while Blower is active) | ** Perform Output Test (Check Air Vents while Blower is active) | ||
* Check wiring and connectors | |||
** Start with the Air Blower Fuse. Is it good? Is it in the CORRECT location in the fuse box? | |||
==== Special Notes ==== | |||
* When found in Audi A4/A5/Q5 (8K/8T/8R) models: | |||
** North American Market (NAR) vehicles, see TPI 2033596/3 (or newer) | |||
** RoW vehicles, see TPI 2022372/2 (or newer) | |||
* When found in Audi TT 8J, the correct fuse location is fuse bank 1, position 12 (Looking down at the fuse box in the engine bay, bank 1 is the top bank and position 12 is the LH end fuse location) | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 00:48, 19 July 2015
01273 - Fresh Air Blower (V2)
Possible Causes
- Fresh Air Blower (V2) defective
- Control Module for Fresh Air Blower (J126) defective
- Short of open circuit in wiring to Fresh Air Blower (V2)
- Climatronic Control Module (J255) malfunctioning
Possible Solutions
- Check Fresh Air Blower (V2)
- Perform Output Test (Check Air Vents while Blower is active)
- Check Meas. Blocks while Blower is active
- Check Control Module for Fresh Air Blower (J126)
- Perform Output Test (Check Air Vents while Blower is active)
- Check wiring and connectors
- Start with the Air Blower Fuse. Is it good? Is it in the CORRECT location in the fuse box?
Special Notes
- When found in Audi A4/A5/Q5 (8K/8T/8R) models:
- North American Market (NAR) vehicles, see TPI 2033596/3 (or newer)
- RoW vehicles, see TPI 2022372/2 (or newer)
- When found in Audi TT 8J, the correct fuse location is fuse bank 1, position 12 (Looking down at the fuse box in the engine bay, bank 1 is the top bank and position 12 is the LH end fuse location)