| Line 10: | Line 10: | ||
* Throttle Actuator (J338) dirty (carbonized) | * Throttle Actuator (J338) dirty (carbonized) | ||
* Throttle Actuator (J338) faulty | * Throttle Actuator (J338) faulty | ||
* Mechanical cable adjusted too tight | |||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check Throttle Actuator (J338) | * Check/Clean Throttle Actuator (J338) | ||
* Adjust mechanical cable | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] | ||
Latest revision as of 14:56, 14 December 2015
17973/P1565/005477 - Throttle Actuator (J338): Lower Stop not Reached
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Throttle Actuator (J338) dirty (carbonized)
- Throttle Actuator (J338) faulty
- Mechanical cable adjusted too tight
Possible Solutions
- Check/Clean Throttle Actuator (J338)
- Adjust mechanical cable