P052F: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
P052F - Control Module for Glow Plugs: Implausible Voltage
- 1.1.1 Possible Symptoms
- 1.2.1 Possible Causes
- 1.3.1 Possible Solutions
- 1.4.1 Special Notes
Created page with "== P052F/001322 - PCV Valve Malfunction == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) active * Noises from engine area ==== Possible Causes ==== * Lea..." |
m Peter moved page P052F/001322 to P052F: dropped the /001322 |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== P052F | == P052F - Control Module for Glow Plugs: Implausible Voltage == | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
* Malfunction Indicator Light (MIL) active | * Malfunction Indicator Light (MIL) active | ||
* | * Glow Plug Indicator Light active | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* | * Voltage error received from the J179-Automatic Glow Time Control Module | ||
* | ** Voltage supply 0.0V (via LIN-Bus message) | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check | * Check power/ground for J179-Automatic Glow Time Control Module | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] | ||
Line 21: | Line 19: | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
Latest revision as of 21:41, 24 August 2021
P052F - Control Module for Glow Plugs: Implausible Voltage
Possible Symptoms
- Malfunction Indicator Light (MIL) active
- Glow Plug Indicator Light active
Possible Causes
- Voltage error received from the J179-Automatic Glow Time Control Module
- Voltage supply 0.0V (via LIN-Bus message)
Possible Solutions
- Check power/ground for J179-Automatic Glow Time Control Module