P161C/005660: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
P161C/005660 - Glowplug for Cylinder 3 (Q12): Open Circuit
- 1.1.1 Possible Symptoms
- 1.2.1 Possible Causes
- 1.3.1 Possible Solutions
- 1.4.1 Special Notes
RtWiKiSyS0p (talk | contribs) New page: __FORCETOC__ == P161C/005660 - Glowplug for Cylinder 3 (Q12): Open Circuit == ==== Possible Symptoms ==== * No Pre-Glow Period * Poor Cold Starting ==== Possible Causes ==== * Glow Plu... |
No edit summary |
||
Line 4: | Line 4: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
* | * Malfunction Indicator Light (MIL) active | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* | * Glowplug for Cylinder 3 (Q12) faulty | ||
* Glow | * Automatic Glow Time Control Module (J179) faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check | * Check Glowplug for Cylinder 3 (Q12) | ||
* Check Glow | * Check Wiring/Connectors from/to Glowplug for Cylinder 3 (Q12) | ||
* Check Automatic Glow Time Control Module (J179) | |||
==== Special Notes ==== | ==== Special Notes ==== |
Latest revision as of 14:56, 23 May 2023
P161C/005660 - Glowplug for Cylinder 3 (Q12): Open Circuit
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Glowplug for Cylinder 3 (Q12) faulty
- Automatic Glow Time Control Module (J179) faulty
Possible Solutions
- Check Glowplug for Cylinder 3 (Q12)
- Check Wiring/Connectors from/to Glowplug for Cylinder 3 (Q12)
- Check Automatic Glow Time Control Module (J179)