Difference between revisions of "00779"
From Ross-Tech Wiki
Gerrit Speek (talk | contribs) |
RtWiKiSyS0p (talk | contribs) m |
||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
== 00779 - Outside Air Temperature Sensor (G17) == | == 00779 - Outside Air Temperature Sensor (G17) == | ||
− | === 00779 - Outside Air Temperature Sensor (G17): Open | + | === 00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus === |
==== Possible Symptoms ==== | ==== Possible Symptoms ==== |
Latest revision as of 11:52, 3 June 2007
00779 - Outside Air Temperature Sensor (G17)
00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster: Open or Short Circuit
Possible Solutions
- Check wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster
- Check Measuring Block Value
00779 - Outside Air Temperature Sensor (G17): Short to Ground
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Outside Air Temperature Sensor (G17) damaged
Possible Solutions
- Check / Replace Outside Air Temperature Sensor (G17)