19558/P3102/012546: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) mNo edit summary |
RtWiKiSyS0p (talk | contribs) No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 4: | Line 4: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
* Hard | * Hard Shudder when turning OFF the Engine | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* Wiring/ | * Fuse(s) faulty | ||
* Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) faulty | |||
* Intake Manifold Flap Motor (V157) faulty | |||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check Wiring/ | * Check Fuse(s) | ||
* Check | * Check Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) | ||
* Check/Replace Intake Manifold Flap Motor (V157) | |||
** Perform Output Test | ** Perform Output Test | ||
__FORCETOC__ | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 21:26, 11 July 2011
19558/P3102/012546 - Motor for Intake Manifold Flap (V157): No Signal
Possible Symptoms
- Hard Shudder when turning OFF the Engine
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157) faulty
- Intake Manifold Flap Motor (V157) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Intake Manifold Flap Motor (V157)
- Check/Replace Intake Manifold Flap Motor (V157)
- Perform Output Test