Difference between revisions of "01329"

From Ross-Tech Wiki
 
m
 
Line 14: Line 14:
 
==== Special Notes ====
 
==== Special Notes ====
  
 +
* This fault code describes that the Convenience System Data Bus is operating in Single Wire mode.
 
* You can check the door control modules by disconnecting all of them and reconnecting them one after another, while checking the comfort system meas. blocks regarding the data bus status.
 
* You can check the door control modules by disconnecting all of them and reconnecting them one after another, while checking the comfort system meas. blocks regarding the data bus status.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 12:09, 17 May 2007

01329 - Convenience System Data Bus in Emergency Mode

Possible Causes

  • Wiring and/or Connectors faulty
  • Door Control Module(s) faulty

Possible Solutions

  • Check/Repair Wiring and/or Connectors
  • Check/Replace Door Control Module(s)

Special Notes

  • This fault code describes that the Convenience System Data Bus is operating in Single Wire mode.
  • You can check the door control modules by disconnecting all of them and reconnecting them one after another, while checking the comfort system meas. blocks regarding the data bus status.