Difference between revisions of "01274"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
Gerrit Speek (talk | contribs) (little spelling mistake) |
||
Line 6: | Line 6: | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
− | * Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) | + | * Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty |
* Positioning Air Flow Flap Positioning Motor (V71) blocked | * Positioning Air Flow Flap Positioning Motor (V71) blocked | ||
* Positioning Air Flow Flap Positioning Motor (V71) faulty | * Positioning Air Flow Flap Positioning Motor (V71) faulty |
Latest revision as of 10:01, 16 December 2007
01274 - Air Flow Flap Positioning Motor (V71)
01274 - Air Flow Flap Positioning Motor (V71): Faulty
Possible Causes
- Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty
- Positioning Air Flow Flap Positioning Motor (V71) blocked
- Positioning Air Flow Flap Positioning Motor (V71) faulty
Possible Solutions
- Check Air Flow Flap Positioning Motor (V71)
- See Measuring Value Blocks (MVB)
- Perform Output Test
- Perform Basic Setting
- Check/Repair Wiring and Connectors