01274 - Air Flow Flap Positioning Motor (V71)

01274 - Air Flow Flap Positioning Motor (V71): Faulty

Possible Causes

  • Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty
  • Positioning Air Flow Flap Positioning Motor (V71) blocked
  • Positioning Air Flow Flap Positioning Motor (V71) faulty

Possible Solutions

  • Check Air Flow Flap Positioning Motor (V71)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test
    • Perform Basic Setting
  • Check/Repair Wiring and Connectors