Difference between revisions of "00260"

From Ross-Tech Wiki
m
 
Line 1: Line 1:
 
__FORCETOC__
 
__FORCETOC__
== 00258 - Solenoid Valve 2 (N89) ==
+
== 00260 - Solenoid Valve 2 (N89) ==
=== 00258 - Solenoid Valve 2 (N89): Open or Short to Ground ===
+
=== 00260 - Solenoid Valve 2 (N89): Open or Short to Ground ===
  
 
==== Possible Causes ====
 
==== Possible Causes ====

Latest revision as of 04:37, 22 March 2007

00260 - Solenoid Valve 2 (N89)

00260 - Solenoid Valve 2 (N89): Open or Short to Ground

Possible Causes

  • Wiring/Connectors from/to Solenoid Valve 2 (N89) Open or Short to Ground
  • Solenoid Valve 2 (N89) faulty

Possible Solutions

  • Check/Repair Wiring/Connectors from/to Solenoid Valve 2 (N89)
  • Check/Replace Solenoid Valve 2 (N89)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test