Difference between revisions of "16987/P0603/001539"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 9: | Line 9: | ||
* Control Module faulty | * Control Module faulty | ||
+ | * Soft Coding for Control Module not correct | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Replace Control Module | * Replace Control Module | ||
+ | * Code Control Module | ||
+ | |||
+ | ==== Special Note ==== | ||
+ | |||
+ | TCM part number 3B0 927 156 AH will have this fault code when new. Perform soft coding of "0001104" and fault should clear. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 08:09, 12 September 2013
16987/P0603/001539 - Internal Control Module: Non-Volatile Memory Error
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Control Module faulty
- Soft Coding for Control Module not correct
Possible Solutions
- Replace Control Module
- Code Control Module
Special Note
TCM part number 3B0 927 156 AH will have this fault code when new. Perform soft coding of "0001104" and fault should clear.