== U0155/049493 - No Communication with Instrument Cluster  ==
+
== 28827/U0155/049493 - No Communication with Instrument Cluster  ==
  
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====

Latest revision as of 07:56, 28 April 2022

28827/U0155/049493 - No Communication with Instrument Cluster

Possible Symptoms

  • Malfunction Indicator Lamp (MIL) active

Possible Causes

  • Connector(s)/Wiring from/to Instrument Cluster faulty
  • Databus Communication faulty

Possible Solutions

  • Check Connector(s)/Wiring from/to Instrument Cluster
  • Check Databus Communication
    • See Measuring Value Blocks (MVB)

Special Notes

  • When found in Engine Control Module without any obvious cause (i.e. Measuring Value Blocks show plausible Values)
    • Check Oil Level and Temperature Sensor Installation Information in Instrument Cluster Adaptation Channel 039.