Difference between revisions of "01331"

From Ross-Tech Wiki
(New page: __FORCETOC__ == 01331 - Door Control Module; Driver Side (J386) == === 01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low === ==== Possible Causes ==== * Fuse(s) fa...)
 
 
(One intermediate revision by the same user not shown)
Line 21: Line 21:
 
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
 
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
 
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
 
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
 +
 +
 +
=== 01331 - Door Control Module; Driver Side (J386): Faulty ===
 +
 +
==== Possible Causes ====
 +
 +
* Fuse(s) faulty
 +
* Wiring/Connectors from/to Control Module faulty
 +
* Door Control Module Driver Side (J386) faulty
 +
 +
==== Possible Solutions ====
 +
 +
* Check Fuse(s)
 +
* Check/Repair Wiring/Connectors from/to Control Module
 +
* Check Door Control Module Driver Side (J386)
 +
 +
 +
=== 01331 - Door Control Module; Driver Side (J386): Single-Wire Operation ===
 +
 +
==== Possible Symptoms ====
 +
 +
* Data Bus Comfort working in Single-Wire Mode
 +
 +
==== Possible Causes ====
 +
 +
* Wiring/Connectors from/to Door Control Module Driver Side (J386)
 +
* Control Module in CAN Data Bus Comfort faulty
 +
 +
==== Possible Solutions ====
 +
 +
* Check Measuring Value Blocks (MVB)
 +
* Check Wiring/Connectors from/to Door Control Module Driver Side (J386)
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 06:58, 22 March 2009

01331 - Door Control Module; Driver Side (J386)

01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low

Possible Causes

  • Fuse(s) faulty
  • Wiring/Connectors from/to Control Module faulty
  • Power Supply (Battery/Generator) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Repair Wiring/Connectors from/to Control Module
  • Check Power Supply (Battery/Generator)

Special Notes

  • When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
  • When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
  • Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.


01331 - Door Control Module; Driver Side (J386): Faulty

Possible Causes

  • Fuse(s) faulty
  • Wiring/Connectors from/to Control Module faulty
  • Door Control Module Driver Side (J386) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Repair Wiring/Connectors from/to Control Module
  • Check Door Control Module Driver Side (J386)


01331 - Door Control Module; Driver Side (J386): Single-Wire Operation

Possible Symptoms

  • Data Bus Comfort working in Single-Wire Mode

Possible Causes

  • Wiring/Connectors from/to Door Control Module Driver Side (J386)
  • Control Module in CAN Data Bus Comfort faulty

Possible Solutions

  • Check Measuring Value Blocks (MVB)
  • Check Wiring/Connectors from/to Door Control Module Driver Side (J386)