Difference between revisions of "01318"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 01318 - Control Module for Injection Pump (J399) == === 01318 - Control Module for Injection Pump (J399): No Elaboration Available === ==== Possible Symptoms ==== * Malf...) |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 01318 - Control Module for Injection Pump (J399) == | == 01318 - Control Module for Injection Pump (J399) == | ||
+ | |||
+ | === 01318 - Control Module for Injection Pump (J399): Signal Outside Specifications === | ||
+ | === 01318 - Control Module for Injection Pump (J399): Implausible Signal === | ||
+ | === 01318 - Control Module for Injection Pump (J399): Faulty === | ||
+ | |||
+ | ==== Possible Symptoms ==== | ||
+ | |||
+ | * Malfunction Indicator Light (MIL) ON | ||
+ | * Limp Mode & Reduced Power/Output | ||
+ | * Emergency/Safety Shut-Off | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Injection Pump (J399) faulty | ||
+ | |||
+ | ==== Possible Solutions ==== | ||
+ | |||
+ | * Check/Replace Injection Pump (J399) | ||
+ | |||
+ | |||
+ | === 01318 - Control Module for Injection Pump (J399): No Communications === | ||
+ | |||
+ | ==== Possible Symptoms ==== | ||
+ | |||
+ | * Malfunction Indicator Light (MIL) ON | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Wiring and/or Connector(s) from/to Injection Pump (J399) faulty | ||
+ | * Injection Pump (J399) faulty | ||
+ | |||
+ | ==== Possible Solutions ==== | ||
+ | |||
+ | * Check Wiring and/or Connector(s) from/to Injection Pump (J399) | ||
+ | * Check Communication to Injection Pump (J399) | ||
+ | ** See Measuring Value Block (MVB) 018 | ||
+ | * Check/Replace Injection Pump (J399) | ||
+ | |||
+ | ==== Special Notes ==== | ||
+ | |||
+ | * When found on 2.5l V6 TDI, has a Compression Test been performed? This code may be stored in Combination with a Compression Test even though the Communication is OK. Under these Circumstances this Fault Code should be cleared. | ||
+ | |||
=== 01318 - Control Module for Injection Pump (J399): No Elaboration Available === | === 01318 - Control Module for Injection Pump (J399): No Elaboration Available === | ||
Line 14: | Line 56: | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
− | * When found on 2.5l V6 TDI, | + | * When found on 2.5l V6 TDI, turn the key OFF, disconnect the car's battery for a few minutes, then re-connect it and try clearing faults again. See TPI # 962201 |
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 15:58, 9 June 2023
01318 - Control Module for Injection Pump (J399)
01318 - Control Module for Injection Pump (J399): Signal Outside Specifications
01318 - Control Module for Injection Pump (J399): Implausible Signal
01318 - Control Module for Injection Pump (J399): Faulty
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Limp Mode & Reduced Power/Output
- Emergency/Safety Shut-Off
Possible Causes
- Injection Pump (J399) faulty
Possible Solutions
- Check/Replace Injection Pump (J399)
01318 - Control Module for Injection Pump (J399): No Communications
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Wiring and/or Connector(s) from/to Injection Pump (J399) faulty
- Injection Pump (J399) faulty
Possible Solutions
- Check Wiring and/or Connector(s) from/to Injection Pump (J399)
- Check Communication to Injection Pump (J399)
- See Measuring Value Block (MVB) 018
- Check/Replace Injection Pump (J399)
Special Notes
- When found on 2.5l V6 TDI, has a Compression Test been performed? This code may be stored in Combination with a Compression Test even though the Communication is OK. Under these Circumstances this Fault Code should be cleared.
01318 - Control Module for Injection Pump (J399): No Elaboration Available
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Control Module Software Issue
Special Notes
- When found on 2.5l V6 TDI, turn the key OFF, disconnect the car's battery for a few minutes, then re-connect it and try clearing faults again. See TPI # 962201