18565/P2133: Difference between revisions
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
 Created page with '__FORCETOC__  == 18565/P2133 - Throttle Position Sensor Bank 2: Signal too High ==  ==== Possible Symptoms ====  * MIL on * Reduced Power Output  ==== Possible Causes ====  * Fau…'  | 
				No edit summary  | 
				||
| (One intermediate revision by the same user not shown) | |||
| Line 23: | Line 23: | ||
* O2 sensor issues can also cause the following DTCs:  | * O2 sensor issues can also cause the following DTCs:  | ||
**16610 - Throttle Pedal Position Sensor (G79): Implausible Signal  | **[[16610/P0226]] - Throttle Pedal Position Sensor (G79): Implausible Signal  | ||
**18560 - Accelerator Position Sensor 2 (G185): Signal too High  | **[[18560/P2128]] - Accelerator Position Sensor 2 (G185): Signal too High  | ||
* In some cases, O2 sensors will damage the ECM.  Ross Tech suggest to replace O2 sensors ''before'' replacing an ECM for this type of issue.  | * In some cases, O2 sensors will damage the ECM.  Ross Tech suggest to replace O2 sensors ''before'' replacing an ECM for this type of issue.  | ||
Latest revision as of 22:50, 16 February 2012
18565/P2133 - Throttle Position Sensor Bank 2: Signal too High
Possible Symptoms
- MIL on
 - Reduced Power Output
 
Possible Causes
- Faulty Accelerator Pedal (very unlikely)
 - Wiring Harness Issue
 - Faulty ECM
 - O2 Sensor(s)
 
Possible Solutions
- Inspect and test Wiring harness for Accelerator Pedal, see Repair Manual
 - Visually inspect O2 sensors for damage
 
Special Notes
- O2 sensor issues can also cause the following DTCs:
- 16610/P0226 - Throttle Pedal Position Sensor (G79): Implausible Signal
 - 18560/P2128 - Accelerator Position Sensor 2 (G185): Signal too High
 
 - In some cases, O2 sensors will damage the ECM. Ross Tech suggest to replace O2 sensors before replacing an ECM for this type of issue.