Difference between revisions of "P189C/006300"
From Ross-Tech Wiki
(Created page with "__FORCETOC__ == 006300-Function Restriction due to Insufficient Pressure Build-Up == === P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up ===...") |
RtWiKiSyS0p (talk | contribs) m (Sebastian moved page 006300 to P189C/006300 without leaving a redirect) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
− | + | == P189C/006300 - Function Restriction due to Insufficient Pressure Build-Up == | |
− | |||
− | |||
− | |||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
Line 20: | Line 17: | ||
* Check/repair/replace faulty wiring/connections. | * Check/repair/replace faulty wiring/connections. | ||
* Check/replace faulty fuse(s). | * Check/replace faulty fuse(s). | ||
− | * Replace Mechatronic Unit. | + | * Replace faulty Mechatronic Unit. |
==== Special Notes ==== | ==== Special Notes ==== | ||
− | * On the | + | * On the 7-Speed Dual Clutch Transmission (DSG/0AM) transmission check for battery power at Pin 9 of the 25-Pin connector. |
− | * Once an effective repair has been completed, faults | + | * Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings. |
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 08:29, 2 December 2013
P189C/006300 - Function Restriction due to Insufficient Pressure Build-Up
Possible Symptoms
- Unable to complete Basic Settings, fault will not clear from Transmission Control Module.
Possible Causes
- Faulty wiring.
- Faulty connections.
- Faulty Fuse(s).
- Faulty Mechatronic Unit, (V401-Hydraulic pump motor)
Possible Solutions
- Check/repair/replace faulty wiring/connections.
- Check/replace faulty fuse(s).
- Replace faulty Mechatronic Unit.
Special Notes
- On the 7-Speed Dual Clutch Transmission (DSG/0AM) transmission check for battery power at Pin 9 of the 25-Pin connector.
- Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.