=== Electronic Damping Control J250 - Basic Settings ===


'''[Select]'''<br>
'''[14 - Susp. Elect]'''<br>
'''[Meas. Blocks - 08]'''<br>
Note the values stores in:'''<br>
Group-054 Field-1 = G78( _Sensor)Min value'''<br>
Group-054 Field-2 = G78( _Sensor)Max value'''<br>
Group-055 Field-1 = G289( _Sensor)Min value'''<br>
Group-055 Field-2 = G289( _Sensor)Max value'''<br>
<br>
Look at:'''<br>
Group-003 Field-1,2,3
- If the values are with in the range of the Min - Max'''<br>
Basic settings can be performed, if not inspect suspension.'''<br>
<br>
'''[Security Access - 16]'''<br>
Enter 31564, to enable the basic setting.'''<br>
'''[Do it!]'''<br>
'''[Basic Settings - 04]'''<br>
Group 001
'''[Go!]'''<br>
<br>
The New values should be displayed.'''<br>
- To check the learned values, check Measuring Value Group-008.'''<br>
[Meas. Blocks - 08]'''<br>
Enter [008] - Go!'''<br>
The values displayed should be the learned values as displayed in the Basic Settings window.'''<br>