| (28 intermediate revisions by 3 users not shown) |
| Line 1: |
Line 1: |
| === Electronic Damping Control J250 - Basic Settings ===
| |
|
| |
|
|
| |
| '''Prerequisites:'''<br>
| |
| - Battery Voltage = 12.0 - 14.0'''<br>
| |
| - No fault codes other than [01087-Basic Setting Not Performed]'''<br>
| |
| - Vehicle is lifted off the ground, on a suitable vehicle lift'''<br>
| |
|
| |
|
| |
| '''[Select]'''<br>
| |
| '''[14 - Susp. Elect]'''<br>
| |
| '''[Meas. Blocks - 08]'''<br>
| |
| Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.'''<br>
| |
| Group-054 Field-1 = G78 - Min value'''<br>
| |
| Group-054 Field-2 = G78 - Max value'''<br>
| |
| <br>
| |
| Group-055 Field-1 = G289 - Min value'''<br>
| |
| Group-055 Field-2 = G289 - Max value'''<br>
| |
| <br>
| |
| '''Look at:'''<br>
| |
| '''Group-003 - Field-1,2,3 - Actual Sensor values'<br>
| |
| - If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then'''<br>
| |
| Basic settings can be performed, if not inspect suspension or sensors.'''<br>
| |
| <br>
| |
| '''[Security Access - 16]'''<br>
| |
| Enter 31564, to enable the basic setting.'''<br>
| |
| '''[Do it!]'''<br>
| |
| '''[Basic Settings - 04]'''<br>
| |
| '''Group 001'''<br>
| |
| '''[Go!]'''<br>
| |
| <br>
| |
| The New values should be displayed.'''<br>
| |
| - To check the learned values, check Measuring Value Group-008.'''<br>
| |
| [Meas. Blocks - 08]'''<br>
| |
| Enter [008] - Go!'''<br>
| |
| The values displayed should be the learned values as displayed in the Basic Settings window.'''<br>
| |