== Coding ==
+
Additional information can be found in the [[Official Factory Repair Information]].
 +
 
 +
 
  
 
== Adaptation ==
 
== Adaptation ==
 +
 +
'''<u>Prerequisites: End Stops</u>'''
 +
* Vehicle system voltage above 12.0v (Engine running)
 +
* All doors and lids shut
 +
* No faults in the [26-Automatic Roof] controller
 +
* Convertible Top in good condition, no damage
 +
* Convertible Top Closed and locked
 +
 +
 +
=== Channel 00: Delete End Stops ===
 +
 +
To reset the learned End Stops, save a new value of 0
 +
* Then follow with the Relearn End Stops.
 +
 +
 +
=== Channel 01: Relearn End Stops ===
 +
 +
To start the relearn the End Stops, save a new value of 1
 +
* Open the Convertible Top to 'Relearn' the End Stops.
 +
* Check for and clear any fault codes.
 +
* Check for proper Convertible Top Operation

Latest revision as of 12:04, 12 April 2018

Additional information can be found in the Official Factory Repair Information.


Adaptation

Prerequisites: End Stops

  • Vehicle system voltage above 12.0v (Engine running)
  • All doors and lids shut
  • No faults in the [26-Automatic Roof] controller
  • Convertible Top in good condition, no damage
  • Convertible Top Closed and locked


Channel 00: Delete End Stops

To reset the learned End Stops, save a new value of 0

  • Then follow with the Relearn End Stops.


Channel 01: Relearn End Stops

To start the relearn the End Stops, save a new value of 1

  • Open the Convertible Top to 'Relearn' the End Stops.
  • Check for and clear any fault codes.