== P052F/001322 - PCV Valve Malfunction ==
== P052F - Control Module for Glow Plugs: Implausible Voltage ==


==== Possible Symptoms ====
==== Possible Symptoms ====


* Malfunction Indicator Light (MIL) active
* Malfunction Indicator Light (MIL) active
* Noises from engine area
* Glow Plug Indicator Light active


==== Possible Causes ====
==== Possible Causes ====


* Leaks in breather system
* Voltage error received from the J179-Automatic Glow Time Control Module
* Crankcase breather elbow failure (see special notes)
** Voltage supply 0.0V (via LIN-Bus message)  
 


==== Possible Solutions ====
==== Possible Solutions ====


* Check breather system
* Check power/ground for J179-Automatic Glow Time Control Module
* Repair/replace failed or leaking parts


[[Category:Fault Codes]]
[[Category:Fault Codes]]
Line 21: Line 19:


==== Special Notes ====
==== Special Notes ====
'''Audi'''
* NAR (North American) Market Audi 3.0L V6 TFSI , please see TSB 17-20-08 / TPI 2060259 for breather elbow concerns.
** https://static.nhtsa.gov/odi/tsbs/2020/MC-10177763-0001.pdf
** TSB/TPI is applicable for these vehicles with the supercharged 3.0L:
*** ''2017 (All) Audi A4 3.0L''
*** ''2013 - 2015 Audi S4 3.0L''
*** ''2015 - 2017 Audi A5 3.0L''
*** ''2012 - 2017 Audi S5 3.0L''
*** ''2012 - 2018 Audi A6/A7 3.0L''
*** ''2011 - 2017 Audi A8 3.0L''
*** ''2013 - 2017 Audi Q5 3.0L''
*** ''2011 - 2019 Audi Q7 3.0L''

Latest revision as of 21:41, 24 August 2021

P052F - Control Module for Glow Plugs: Implausible Voltage

Possible Symptoms

  • Malfunction Indicator Light (MIL) active
  • Glow Plug Indicator Light active

Possible Causes

  • Voltage error received from the J179-Automatic Glow Time Control Module
    • Voltage supply 0.0V (via LIN-Bus message)

Possible Solutions

  • Check power/ground for J179-Automatic Glow Time Control Module