Difference between revisions of "00538"

From Ross-Tech Wiki
 
Line 1: Line 1:
__FORCETOC__
+
== 00538 - Reference Voltage ==
== 00538 - Reference voltage ==
 
  
=== 00538  - Reference voltage : Signal too large ===
+
=== 00538  - Reference Voltage : Signal too large ===
=== 00538  - Reference voltage : Signal too small ===
+
=== 00538  - Reference Voltage : Signal too small ===
  
==== Possible Cause ====
+
==== Possible Causes ====
  
* Short circuit or open circuit in wiring or connectors. Pay special attention to the wires from contact 8 of connector housing T16b on Climatronic control module -J255- to flap motors.<br>
+
* Common Causes
 +
** Fuse(s) faulty
 +
** Wiring and/or Connector(s) from/to Control Module faulty
 +
** Control Module faulty
 +
* Heating/Climate Control specific Causes
 +
** Fuse(s) faulty
 +
** Wiring and/or Connector(s) from/to Control Module for Heating/Climate Control (J255/J301) faulty
 +
** Flap Motor/Position Sensor faulty
 +
** Control Module for Heating/Climate Control (J255/J301) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
* Check wiring and connectors to control module using wiring diagram<br>
+
* Common Solutions
* Check function of flap motors for regulating air conditioner using function 03 Output Diagnostic Test Mode (DTM).<br>
+
** Check/Replace Fuse(s)
 +
** Check/Repair Wiring and/or Connector(s) from/to Control Module
 +
** Check/Replace Control Module
 +
* Heating/Climate Control specific Solutions
 +
** Check/Replace Fuse(s)
 +
** Check/Repair Wiring and/or Connector(s) from/to Control Module for Heating/Climate Control (J255/J301)
 +
** Check/Replace Flap Motor/Position Sensor
 +
*** Perform Output Test
 +
** Control Module for Heating/Climate Control (J255/J301)
  
==== Possible Cause ====
+
==== Special Notes ====
  
* Flap position sensors -G92-, -G112-, -G113- or -G114- malfunctioning. <br>
+
* When found in Control Module for Heating/Climate Control (J255/J301):
 +
** Disconnect the electrical Connectors to the Position Sensors one after another, erase Fault Codes and check Fault Codes again. If the "Reference Voltage" Fault Code is no longer recognized (and the Fault Code for the reappears after reconnecting), the applicable Flap Motor/Position Sensor must be replaced.
  
==== Possible Solutions ====
 
  
* Disconnect electrical connectors to listed sensors one after another, erase DTC memory and check DTC memory again. If the "Reference voltage" malfunction is no longer recognized (and the DTC reappears after reconnecting), the applicable flap motor must be replaced.<br>
+
=== 00538  - Reference Voltage : Faulty ===
  
==== Possible Cause ====
+
==== Possible Causes ====
  
* Control module malfunctioning. <br>
+
* Fuse(s) faulty
 +
* Wiring and/or Connector(s) from/to Battery faulty
 +
* Control Module faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
* Replace control module if necessary. <br>
+
* Check Fuse(s)
 +
* Check Wiring and/or Connector(s) from/to Battery
 +
* Check/Replace Control Module
 +
 
 +
==== Special Notes ====
 +
 
 +
* When found in Central Electronics Control Module (J519):
 +
** Specifically check the (Ground) Wiring from the Central Electronics Control Module (J519) to the Battery.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]
 +
__FORCETOC__

Revision as of 06:23, 11 March 2011

00538 - Reference Voltage

00538 - Reference Voltage : Signal too large

00538 - Reference Voltage : Signal too small

Possible Causes

  • Common Causes
    • Fuse(s) faulty
    • Wiring and/or Connector(s) from/to Control Module faulty
    • Control Module faulty
  • Heating/Climate Control specific Causes
    • Fuse(s) faulty
    • Wiring and/or Connector(s) from/to Control Module for Heating/Climate Control (J255/J301) faulty
    • Flap Motor/Position Sensor faulty
    • Control Module for Heating/Climate Control (J255/J301) faulty

Possible Solutions

  • Common Solutions
    • Check/Replace Fuse(s)
    • Check/Repair Wiring and/or Connector(s) from/to Control Module
    • Check/Replace Control Module
  • Heating/Climate Control specific Solutions
    • Check/Replace Fuse(s)
    • Check/Repair Wiring and/or Connector(s) from/to Control Module for Heating/Climate Control (J255/J301)
    • Check/Replace Flap Motor/Position Sensor
      • Perform Output Test
    • Control Module for Heating/Climate Control (J255/J301)

Special Notes

  • When found in Control Module for Heating/Climate Control (J255/J301):
    • Disconnect the electrical Connectors to the Position Sensors one after another, erase Fault Codes and check Fault Codes again. If the "Reference Voltage" Fault Code is no longer recognized (and the Fault Code for the reappears after reconnecting), the applicable Flap Motor/Position Sensor must be replaced.


00538 - Reference Voltage : Faulty

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Battery faulty
  • Control Module faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Battery
  • Check/Replace Control Module

Special Notes

  • When found in Central Electronics Control Module (J519):
    • Specifically check the (Ground) Wiring from the Central Electronics Control Module (J519) to the Battery.