Difference between revisions of "01274"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) |
RtWiKiSyS0p (talk | contribs) m |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 01274 - Air Flow Flap Positioning Motor (V71) == | == 01274 - Air Flow Flap Positioning Motor (V71) == | ||
+ | |||
+ | === 01274 - Air Flow Flap Positioning Motor (V71): Faulty === | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
− | * | + | * Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty |
− | * Air Flow Flap Motor (V71) | + | * Positioning Air Flow Flap Positioning Motor (V71) blocked |
− | * Air Flow Flap Motor (V71) | + | * Positioning Air Flow Flap Positioning Motor (V71) faulty |
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
− | * Check Air Flow Flap Motor (V71) | + | * Check Air Flow Flap Positioning Motor (V71) |
− | * Perform Output Test | + | ** See Measuring Value Blocks (MVB) |
− | * Perform Basic Setting | + | ** Perform Output Test |
− | * Check/Repair Wiring and Connectors | + | ** Perform Basic Setting |
− | + | * Check/Repair Wiring and Connectors | |
− | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 13:56, 14 March 2007
01274 - Air Flow Flap Positioning Motor (V71)
01274 - Air Flow Flap Positioning Motor (V71): Faulty
Possible Causes
- Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty
- Positioning Air Flow Flap Positioning Motor (V71) blocked
- Positioning Air Flow Flap Positioning Motor (V71) faulty
Possible Solutions
- Check Air Flow Flap Positioning Motor (V71)
- See Measuring Value Blocks (MVB)
- Perform Output Test
- Perform Basic Setting
- Check/Repair Wiring and Connectors