Difference between revisions of "00258"
From Ross-Tech Wiki
Gerrit Speek (talk | contribs) |
RtWiKiSyS0p (talk | contribs) |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
− | == 00258 - Solenoid | + | == 00258 - Solenoid Valve 1 (N88) == |
+ | === 00258 - Solenoid Valve 1 (N88): Open or Short to Ground === | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
− | * Open | + | * Wiring/Connectors from/to Solenoid Valve 1 (N88) Open or Short to Ground |
− | * ( | + | * Solenoid Valve 1 (N88) faulty |
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
− | * Check | + | * Check/Repair Wiring/Connectors from/to Solenoid Valve 1 (N88) |
− | * Replace N88 | + | * Check/Replace Solenoid Valve 1 (N88) |
+ | ** See Measuring Value Blocks (MVB) | ||
+ | ** Perform Output Test | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 04:36, 22 March 2007
00258 - Solenoid Valve 1 (N88)
00258 - Solenoid Valve 1 (N88): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to Solenoid Valve 1 (N88) Open or Short to Ground
- Solenoid Valve 1 (N88) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Solenoid Valve 1 (N88)
- Check/Replace Solenoid Valve 1 (N88)
- See Measuring Value Blocks (MVB)
- Perform Output Test