Difference between revisions of "3.0l V6 TDI (BKS/BMK/BUN)"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) m |
||
Line 39: | Line 39: | ||
MVB 100.4: Regeneration Abort recognized ''(0 = No Abort/1 = Abort recognized)''<br> | MVB 100.4: Regeneration Abort recognized ''(0 = No Abort/1 = Abort recognized)''<br> | ||
MVB 101.4: Regeneration Status ''(001 = Heating Up, 010 = Regeneration, 100 = Cooling Down)''<br> | MVB 101.4: Regeneration Status ''(001 = Heating Up, 010 = Regeneration, 100 = Cooling Down)''<br> | ||
− | + | MVB 102.1: Temperature before Catalyst<br> | |
− | + | MVB 102.2: Temperature before Particle Filter<br> | |
'''[Done, Go Back]'''<br> | '''[Done, Go Back]'''<br> | ||
'''[Close Controller, Go Back - 06]'''<br><br> | '''[Close Controller, Go Back - 06]'''<br><br> |
Revision as of 08:24, 24 March 2007
Coding
Coding-II
- 10016 = Particle Filter Emergency Regeneration
Adaptation
Basic Setting
Special Functions
Particle Filter Emergency Regeneration
Prerequisites:
- Ignition ON
- Engine ON (Idle)
- Oil Temperature above 70 °C (see MVB 007.2)
- Particle Filter Load below 68g (see MVB 104.3)
- Engine Hood CLOSED
- Parking Brake ENGAGED
- Transmission in (P)ARK
- Temperatures at the Exhaust System may rise up to 300 °C!!!
- No Fault Codes Stored
- Power Consumers ON (Light, Seat Heating, Front/Rear Window Heater, Climate Control)
The Regeneration may take up to 40 minutes, the engine speed automatically increases to about 1500 RPM.
[Select]
[01 - Engine]
[Coding-II - 11]
- Start Regeneration by Entering 10016.
[Do It!]
[Meas. Blocks - 08]
Select all 3 Groups at once 100, 101 and 102
[Go!]
MVB 100.1: Engine Speed
MVB 100.3: Regeneration Counter/Timer
MVB 100.4: Regeneration Abort recognized (0 = No Abort/1 = Abort recognized)
MVB 101.4: Regeneration Status (001 = Heating Up, 010 = Regeneration, 100 = Cooling Down)
MVB 102.1: Temperature before Catalyst
MVB 102.2: Temperature before Particle Filter
[Done, Go Back]
[Close Controller, Go Back - 06]