18237/P1829 - Pressure Control Valve 4 (N218): Open/Short to Ground

Possible Causes

  • Wiring from/to Pressure Control Valve 4 (N218) Open/Short to Ground
  • Pressure Control Valve 4 (N218) faulty

Possible Solutions

  • Check Wiring from/to Pressure Control Valve 4 (N218)
  • Check Pressure Control Valve 4 (N218)
  • Check Measuring Blocks

Special Notes

  • Pressure Control Valve 4 (N218) might be referred to as Solenoid Valve 7 (N94)
  • Some 02E transmissions (DSG) will not have (N218) or (N94) listed in the factory repair manual. It is part of the Mechatronics Unit.
  • Start with checking connectors for corrosion or water damage, in case of 01V transmission pay special attention to 16-pin connector between valve body and wiring harness.