Revision as of 13:47, 11 October 2010
16987/P0603/001539 - Internal Control Module: Non-Volatile Memory Error
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Control Module faulty
Possible Solutions
- Replace Control Module
Special Note
TCM part number 3B0 927 156 AH will have this fault code when new. Perform soft coding of "0001104" and fault should clear.