Difference between revisions of "16987/P0603/001539"

From Ross-Tech Wiki
m
 
Line 13: Line 13:
  
 
* Replace Control Module
 
* Replace Control Module
 +
 +
==== Special Note ====
 +
 +
TCM part number 3B0 927 156 AH will have this fault code when new.  Perform soft coding of "0001104" and fault should clear.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 13:47, 11 October 2010

16987/P0603/001539 - Internal Control Module: Non-Volatile Memory Error

Possible Symptoms

  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Control Module faulty

Possible Solutions

  • Replace Control Module

Special Note

TCM part number 3B0 927 156 AH will have this fault code when new. Perform soft coding of "0001104" and fault should clear.