02830: Difference between revisions

No edit summary
 
mNo edit summary
Line 8: Line 8:
* Supply Voltage insufficient
* Supply Voltage insufficient
* Control Module Coding incorrect
* Control Module Coding incorrect
* Incorrect Control Module installed


==== Possible Solutions ====
==== Possible Solutions ====


* Check Control Module Power Supply
* Check Control Module Power Supply
* Check CAN-Gateway Coding ''(see [[Diagnostic Procedures|Vehicle specific Diagnostic Procedures]])''.
* Check Control Module Coding ''(see [[Diagnostic Procedures|Vehicle specific Diagnostic Procedures]])''.
* Check CAN-Databus Powertrain Cut-Off Relay (J788)
* Check CAN-Databus Powertrain Cut-Off Relay (J788)
** Check Measuring Value Blocks (MVB)
** Check Measuring Value Blocks (MVB)
** Perform Output Test and check for an audible noise while the Relay is being actuated.
** Perform Output Test and check for an audible noise while the Relay is being actuated.
* Check if Control Module (Part Number) fits the Car's Equipment


==== Special Notes ====
==== Special Notes ====

Revision as of 13:49, 23 September 2007

02830 - Control Circuit for CAN Isolator for Driver Assistance Systems

02830 - Control Circuit for CAN Isolator for Driver Assistance Systems: Electrical Fault in Circuit

Possible Causes

  • Supply Voltage insufficient
  • Control Module Coding incorrect
  • Incorrect Control Module installed

Possible Solutions

  • Check Control Module Power Supply
  • Check Control Module Coding (see Vehicle specific Diagnostic Procedures).
  • Check CAN-Databus Powertrain Cut-Off Relay (J788)
    • Check Measuring Value Blocks (MVB)
    • Perform Output Test and check for an audible noise while the Relay is being actuated.
  • Check if Control Module (Part Number) fits the Car's Equipment

Special Notes

  • When found in VW Passat (3C): CAN-Gateway, check Measuring Value Block (MVB) 002.3 while cycling the Ignition. It should change between active and passive.