Line 17: | Line 17: | ||
'''<u>Prerequisites:</u>'''<br> | '''<u>Prerequisites:</u>'''<br> | ||
− | * | + | * Potentiometer / Flap replyed |
+ | * OR Climatronic Control Module (J255) replaced | ||
+ | * OR Climatronic Control Module (J255) recoded | ||
'''[Select]'''<br> | '''[Select]'''<br> |
Revision as of 10:43, 21 November 2007
Coding
- 000xx?0: Glass Type
- 2 = Standard Glass (Clear Glass)
- 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
- 000x?x0: Roof
- 0 = Solar Roof not installed
- 2 = Solar Roof installed
- 000?xx0: Refrigerant Loss Recognition
- 0 = Refrigerant Temperature Sensor installed (Recognition activated)
- 1 = Refrigerant Temperature Sensor not installed (Recognition deactivated)
Basic Setting
Normal (Potentiometer & Flap Adaptation)
Prerequisites:
- Potentiometer / Flap replyed
- OR Climatronic Control Module (J255) replaced
- OR Climatronic Control Module (J255) recoded
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 001
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The basic setting takes approximately 25 seconds.
[Done, Go Back]
[Close Controller, Go Back - 06]
Service Position
Notes:
- Has to be performed before ANY Actuators/Motors are being removed.
- While in Service Position the Display reads SF (German for "Servicefall").
- Make sure to have the Ignition OFF while working on the Actuators/Motors.
- Once all work has been done, switch ON the Ignition and perform the normal Basic Setting (Potentiometer & Flap Adaptation).
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 002
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The Display should read SFnow.
[Done, Go Back]
[Close Controller, Go Back - 06]