Difference between revisions of "VW Touareg (7L) Heating/Air Conditioning"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) |
||
Line 2: | Line 2: | ||
== Coding == | == Coding == | ||
− | * ''' | + | * '''00xxx?0''': ''Glass Type'' |
** 2 = Standard Glass (Clear Glass) | ** 2 = Standard Glass (Clear Glass) | ||
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) | ** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) | ||
− | * ''' | + | * '''00xx?x0''': ''Roof'' |
− | ** 0 = Solar Roof not installed | + | ** 0 = Solar Roof not installed & Anti-Whistle Measures inactive |
+ | ** 1 = Anti-Whistle Measures active (only older Climate Control Units) | ||
** 2 = Solar Roof installed | ** 2 = Solar Roof installed | ||
− | * ''' | + | ** 3 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic) |
+ | ** 4 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic) | ||
+ | ** 5 = Solar Roof not installed & Anti-Whistle Measures inactive & Without Acoustic Package | ||
+ | ** 6 = Anti-Whistle Measures active (only older Climate Control Units) & Without Acoustic Package | ||
+ | ** 7 = Solar Roof installed & Without Acoustic Package | ||
+ | ** 8 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package | ||
+ | ** 9 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package | ||
+ | * '''00x?xx0''': ''Refrigerant Loss Recognition'' | ||
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)'' | ** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)'' | ||
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)'' | ** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)'' | ||
− | + | ** 2 = Refrigerant Temperature Sensor installed ''(Recognition activated / V6 FSI Engine)'' | |
+ | * '''00?xxx0''': ''Options'' | ||
+ | ** +1 = Climate Control Activation Delay (140 ms) active | ||
+ | ** +2 = Anti-Fog Measures active (Hot Country/"Florida" Coding) | ||
== Basic Setting == | == Basic Setting == |
Latest revision as of 09:12, 30 January 2008
Coding
- 00xxx?0: Glass Type
- 2 = Standard Glass (Clear Glass)
- 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
- 00xx?x0: Roof
- 0 = Solar Roof not installed & Anti-Whistle Measures inactive
- 1 = Anti-Whistle Measures active (only older Climate Control Units)
- 2 = Solar Roof installed
- 3 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic)
- 4 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic)
- 5 = Solar Roof not installed & Anti-Whistle Measures inactive & Without Acoustic Package
- 6 = Anti-Whistle Measures active (only older Climate Control Units) & Without Acoustic Package
- 7 = Solar Roof installed & Without Acoustic Package
- 8 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
- 9 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
- 00x?xx0: Refrigerant Loss Recognition
- 0 = Refrigerant Temperature Sensor installed (Recognition activated)
- 1 = Refrigerant Temperature Sensor not installed (Recognition deactivated)
- 2 = Refrigerant Temperature Sensor installed (Recognition activated / V6 FSI Engine)
- 00?xxx0: Options
- +1 = Climate Control Activation Delay (140 ms) active
- +2 = Anti-Fog Measures active (Hot Country/"Florida" Coding)
Basic Setting
Normal (Potentiometer & Flap Adaptation)
Prerequisites:
- Potentiometer / Flap replyed
- OR Climatronic Control Module (J255) replaced
- OR Climatronic Control Module (J255) recoded
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 001
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The basic setting takes approximately 25 seconds.
[Done, Go Back]
[Close Controller, Go Back - 06]
Service Position
Notes:
- Has to be performed before ANY Actuators/Motors are being removed.
- While in Service Position the Display reads SF (German for "Servicefall").
- Make sure to have the Ignition OFF while working on the Actuators/Motors.
- Once all work has been done, switch ON the Ignition and perform the normal Basic Setting (Potentiometer & Flap Adaptation).
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 002
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The Display should read SFnow.
[Done, Go Back]
[Close Controller, Go Back - 06]