Difference between revisions of "01331"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 01331 - Door Control Module; Driver Side (J386) == === 01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low === ==== Possible Causes ==== * Fuse(s) fa...) |
RtWiKiSyS0p (talk | contribs) |
||
Line 21: | Line 21: | ||
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | * When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | ||
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored. | * Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored. | ||
+ | |||
+ | |||
+ | === 01331 - Door Control Module; Driver Side (J386): Faulty === | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Fuse(s) faulty | ||
+ | * Wiring/Connectors from/to Control Module faulty | ||
+ | * Door Control Module Driver Side (J386) faulty | ||
+ | |||
+ | ==== Possible Solutions ==== | ||
+ | |||
+ | * Check Fuse(s) | ||
+ | * Check/Repair Wiring/Connectors from/to Control Module | ||
+ | * Check Door Control Module Driver Side (J386) | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 10:17, 14 January 2009
01331 - Door Control Module; Driver Side (J386)
01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low
Possible Causes
- Fuse(s) faulty
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check Fuse(s)
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
- Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
01331 - Door Control Module; Driver Side (J386): Faulty
Possible Causes
- Fuse(s) faulty
- Wiring/Connectors from/to Control Module faulty
- Door Control Module Driver Side (J386) faulty
Possible Solutions
- Check Fuse(s)
- Check/Repair Wiring/Connectors from/to Control Module
- Check Door Control Module Driver Side (J386)