02251 - Heater Unit Locked
-
1.1.1
02251 - Heater Unit Locked
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
-
1.1.1
02251 - Heater Unit Locked
RtWiKiSyS0p (talk | contribs) mNo edit summary |
|||
Line 6: | Line 6: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
* Heater not working | * Heater not working | ||
* Heater | * Heater Module refuses to clear Fault Codes | ||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* | * Fuel Level low | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== |
Revision as of 08:13, 6 October 2008
02251 - Heater Unit Locked
02251 - Heater Unit Locked
Possible Symptoms
- Heater not working
- Heater Module refuses to clear Fault Codes
Possible Causes
- Fuel Level low
Possible Solutions
- When found in Aux Heater module of VW Touran (and possibly similar models), unlock heater module by saving a 1 in Adaptation Channel 42, then clear fault codes.