Difference between revisions of "19804/P3348/013128"

From Ross-Tech Wiki
(New page: == 19804/P3348/013128 - Control Circuit for Controller for Turbocharger 1 (J724): Electrical Malfunction == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) ON ==== Possi...)
 
m
Line 17: Line 17:
 
* Check/Replace Controller for Turbocharger 1 (J724)
 
* Check/Replace Controller for Turbocharger 1 (J724)
 
** Perform (Selective) Output Test, the Blade Positions should change visibly and audibly
 
** Perform (Selective) Output Test, the Blade Positions should change visibly and audibly
 +
** Perform System Test using VAS 6395
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]
 
__FORCETOC__
 
__FORCETOC__
 
__NOEDITSECTION__
 
__NOEDITSECTION__

Revision as of 13:15, 21 January 2010

19804/P3348/013128 - Control Circuit for Controller for Turbocharger 1 (J724): Electrical Malfunction

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Controller for Turbocharger 1 (J724) faulty
  • Controller for Turbocharger 1 (J724) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Controller for Turbocharger 1 (J724)
  • Check/Replace Controller for Turbocharger 1 (J724)
    • Perform (Selective) Output Test, the Blade Positions should change visibly and audibly
    • Perform System Test using VAS 6395