Difference between revisions of "17971/P1563/005475"
From Ross-Tech Wiki
(→Notes) |
|||
Line 25: | Line 25: | ||
* On the 1.9L ALH TDI engine: | * On the 1.9L ALH TDI engine: | ||
− | ** The Quantity Adjuster (N146) should ohm test between .5 and 2.5 Ω. | + | ** The Quantity Adjuster (N146) should ohm test between 0.5 and 2.5 Ω. |
** With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts. | ** With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 16:26, 17 August 2011
17971/P1563/005475 - Quantity Adjuster (N146): Lower Limit Reached
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Reduced Power
- Engine jerking
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Quantity Adjuster (N146) faulty
- Quantity Adjuster (N146) not adjusted
- Quantity Adjuster (N146) blocked/faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Quantity Adjuster (N146)
- Check/Adjust Quantity Adjuster (N146)
- Check/Replace Injection Pump
Notes
- On the 1.9L ALH TDI engine:
- The Quantity Adjuster (N146) should ohm test between 0.5 and 2.5 Ω.
- With the coolant above 85° C, MVB 001, Field 3 should read between 1.45 to 2.0 Volts.