P189C/006300: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
Created page with "__FORCETOC__ == 006300-Function Restriction due to Insufficient Pressure Build-Up == === P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up ===..." |
No edit summary |
||
Line 20: | Line 20: | ||
* Check/repair/replace faulty wiring/connections. | * Check/repair/replace faulty wiring/connections. | ||
* Check/replace faulty fuse(s). | * Check/replace faulty fuse(s). | ||
* Replace Mechatronic Unit. | * Replace faulty Mechatronic Unit. | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
* On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector. | * On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector. | ||
* Once an effective repair has been completed, faults | * Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 00:46, 26 June 2012
006300-Function Restriction due to Insufficient Pressure Build-Up
P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up
Possible Symptoms
- Unable to complete Basic Settings, fault will not clear from Transmission Control Module.
Possible Causes
- Faulty wiring.
- Faulty connections.
- Faulty Fuse(s).
- Faulty Mechatronic Unit, (V401-Hydraulic pump motor)
Possible Solutions
- Check/repair/replace faulty wiring/connections.
- Check/replace faulty fuse(s).
- Replace faulty Mechatronic Unit.
Special Notes
- On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector.
- Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.