17832/P1424/005156 - Secondary Air Injection System; Bank 1: Leak Detected
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Piping between Secondary Air Injection Pump and Secondary Air Injection Valve leaking
- Faulty Kombi Valve
Possible Solutions
- Check Piping between Secondary Air Injection Pump and Secondary Air Injection Valve
- Replace faulty Kombi Valve