* Fresh Air Blower (V2) defective
 
* Fresh Air Blower (V2) defective
 
* Control Module for Fresh Air Blower (J126) defective
 
* Control Module for Fresh Air Blower (J126) defective
 +
* Wiring defective
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
Line 14: Line 15:
 
* Check Control Module for Fresh Air Blower (J126)
 
* Check Control Module for Fresh Air Blower (J126)
 
** Perform Output Test (Check Air Vents while Blower is active)
 
** Perform Output Test (Check Air Vents while Blower is active)
 +
* Check wiring
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 05:00, 22 April 2006

01273 - Fresh Air Blower (V2)

Possible Causes

  • Fresh Air Blower (V2) defective
  • Control Module for Fresh Air Blower (J126) defective
  • Wiring defective

Possible Solutions

  • Check Fresh Air Blower (V2)
    • Perform Output Test (Check Air Vents while Blower is active)
    • Check Meas. Blocks while Blower is active
  • Check Control Module for Fresh Air Blower (J126)
    • Perform Output Test (Check Air Vents while Blower is active)
  • Check wiring