17965/P1557/005463: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) mNo edit summary |
Gerrit Speek (talk | contribs) |
||
Line 6: | Line 6: | ||
* Boost pressure too high | * Boost pressure too high | ||
* Reduced power output | * Reduced power output | ||
* Limp mode | |||
==== Possible Causes ==== | ==== Possible Causes ==== |
Revision as of 13:18, 3 June 2006
17965/P1557/005463 - Charge Pressure Control: Positive Deviation
Possible Symptoms
- Boost pressure too high
- Reduced power output
- Limp mode
Possible Causes
- Hoses/Pipes incorrect connected, disconnected, blocked or leaking
- Charger Pressure Control defective
- Solenoid Valve for Boost Pressure Control (N75) defective
Possible Solutions
- Check Hoses/Pipes to/between Components
- Check Charge Pressure Control
- Check Solenoid Valve for Boost Pressure Control (N75)